Tip: if you're looking for drivers, manuals, or other technical support resources, search in the Stevens support site instead.

Cellular

GOES

900MHz

Teledesign TS4000 900MHz UHF/VHF

eTracker
True cloud-based sensor configuration, logging, reporting and data analysis all-in-one.

Bluetooth

Shark (RS232/RS485 Bluetooth Serial Adapter)

Software

Stevens-Connect
A cloud-based interface to configure hardware, visualize data, analyze measurements, manage alarms, calculations, and set up data routing.


MEASUREMENTS TO MIND (M2M) is a growing suite of Stevens products that embraces cloud-computing with an all-inclusive vision of shortening the communication path from the sensors to data on-line. That is, what the sensors MEASURE the MIND sees.


The product finder lets you explore our catalog visually and filter products by type of monitoring, manufacturer, and more.

Power

SOLO (smart SDI-12 power manager)
JL-2 (solar charge controller)
Batteries
Power Supplies
Solar Panels

SOLO
Smart SDI-12 power manager that also provides remote power cycling.


The product finder lets you explore our catalog visually and filter products by type of monitoring, manufacturer, and more.


The product finder lets you explore our catalog visually and filter products by type of monitoring, manufacturer, and more.


DataLogIC 3000

Data logger

Part # 93750

datalogic

The DataLogic 3000 is a full-featured logger that will meet the data acquisition, processing, control and communication requirements of even complex stations.

Data is stored internally and also backed up on a removable SD Card (up to 2GB) for additional redundancy and easy transfer to your computer.

Windows software allows easy programming of logging and the reporting of sensors and telemetry interface, offsets, basic math, and alarm conditions—all with a simple graphical interface.

Each sensor input port has isolated lightning protection. A 24 VDC loop power supply provides sufficient current to drive sensors. The analog input channels can automatically select measurement range based on the signal level. These channels are isolated and offer voltage protection to provide reliable monitoring in noisy environments.

Supported measurement and sensor types include temperature, 0-5 vdc, current, 4-20mA loops, resistance, bridges, strain gauges, quadrature and frequency—all returned in engineering units of your choice. Switchable excitation and triggering are provided on all channels to simplify wiring and installation.

The DataLogIC 3000 provides several popular data bus I/O’s including; SDI-12 (Version 1.3), ModBus (optional), CAN Bus (optional), two RS-232 ports, RS-485 (optional), and USB 2.0.

Connecting to modems, GPS, scales, PLC’s, and other intelligent devices is made simple with a separate serial port on the back panel offering high-speed communications.

Datalogger Comparison

Which Stevens data logger is right for your application?

FEATURE

DATALOGIC 3000

Sensor inputs

DATALOGIC 3000

9 analog (0-5V & 4-20mA) / 1 pulse / 1 SDI-12

4 analog (0-5V & 4-20mA) / 1 pulse / 1 SDI-12

Sensor power

24 VDC, 12 VDC, 5 VDC, (12VDC & 24VDC under firmware control)

Memory

Internal 2 GB flash / removable 2 GB SD Card

Serial ports

DATALOGIC 3000

2 RS-232 / 1 USB 2.0

1 RS-232 / 1 USB 2.0

Output

1 control output 0 – 5 V (steady state or pulse)

Touchscreen display option

DATALOGIC 3000

Request Quote

Touchscreen Display Enclosure

The DataLogIC 3000 can be ordered as an all-in-one system that enables easy configuration via a touchscreen display, without the need for an external computer.

Using the touch screen, users can configure the data logger and easily download data on the SD card and/or a USB-A thumb drive, which can be removed for data offloading and backup.

The touchscreen display operates with included LoggerSet mobile software, which features the same functionality as the standard Windows-based LoggerSet software. Anyone who needs to access the logger in the field can easily turn on the touchscreen and update the configuration file or manage collected data. The touchscreen display is off when not in use, consuming no power.

The complete package includes the display and the DataLogIC 3000 mounted in an NEMA 4 enclosure (12" H x 10" W x 6" D). The enclosure has room for sensor terminal connections, a radio, SOLO smart SDI-12 power management control and a 12 VDC / 9 amp battery.

Watertight cable ports on the bottom of the NEMA-4 enclosure allow sensor, communication, and any external power cables to be routed into the enclosure. These ports can be selected and customized by request for specific applications.

Front

DataLogIC 3000 touchscreen display and enclosure.

Inside

The inside has room for a 12 VDC / 9 amp battery, SOLO power management controller, radio, and cables.

Rotate

The DataLogIC 3000 mount can pivot to provide easy access to I/O ports.


Technical Specifications

Key Features

Processor

32-bit ARM, 16-bit TI MSP430, and two 16-bit dsPIC microprocessors

On-board data storage

2 GB internal FLASH storage, plus removable 2 GB on SD memory card

Non-volatile memory

All setup parameters and clock, lithium battery backup

Real-time clock

Accurate to ±1 minute/month, leap year correction, temperature correction

Watchdog timer

System resets upon microprocessor failure

Digital to analog (0-5 VDC) output

12-bit resolution

Serial ports

  • Two (2) RS-232, minimum ±5 VDC levels, 4800 to 38400 baud (115K baud for video)
  • One (1) USB 2.0

Communications

  • Two (2) RS-232
  • One (1) USB 2.0 (fully compatible with USB 1.0 devices)
  • RS-485 (optional)
  • 10/100 Base-T Ethernet (TCP/IP) (optional), auto sensing power-over-ethernet (PoE) available
  • Wi-Fi (optional)

Optional camera input

Full support for NTSC & PAL, storage of video and images to on-board memory

Power requirements

9.6 to 16 VDC, 4 mA standby current (telemetry system may require additional power)

Logging interval

1 minute to 24 hours

Message size

6 - 250 bytes typical, no maximum

Sensor Input

Channels

9 analog channels, 8 single-ended,
5 differential ended

Input type

2 wire, 4 - 20 mA current loop

Sensor power

24 VDC, 12 VDC, 5 VDC, (12 & 24 VDC under firmware control)

Accuracy & resolution

0.01% accuracy, 0.002% resolution

Analog to digital (0-5 VDC)

21-bit resolution
Input impedance: 10 K ohm (min)

Pulse counter

Input type: pulse
Sensor power: 5 or 12 VDC continuous
Maximum rate: 60 pulses per minute
High data rate mode: up to 40 MHz

Serial:

Input type: SDI-12
Sensor power: 5 VDC or 12 VDC continuous, 12 VDC under firmware control (switched)

Switched excitation voltages

12V and 24V

Environmental

Temperature and humidity

Operating: -40°F to 158°F (-40°C to 70°C)
NEMA 4 enclosure: 100% condensing
Aluminum enclosure: 95% non-condensing

Physical size

6.5" x 4.5" x 2.3" (165.1 mm x 114.3 mm x 58.4 mm)