Barometric pressure sensors convert absolute atmospheric pressure into a linear, proportional voltage, which may be used in any meteorological program. The Met One 092 barometric pressure sensor brings in modern digital computer technology. An on-board CPU scales pressure measurements, provides temperature compensation and controls communications output.

This sensor is inherently stable and does not require periodic service or routine recalibration.

The enclosure houses a solid state pressure transducer, with linearization and amplification electronics along with a low power embedded CPU. The sensor is contained within a small polycarbonate enclosure, and may be mounted outside or inside a building or other enclosure. Small inlet holes allow the atmospheric pressure access to the sensing element.

  • Compact size
  • Weatherproof enclosure
  • Digital and analog outputs
  • Permanent calibration; no service required
  • Customer configured output

Shop Online

What's the Easiest and Quickest Way to Start Collecting Data and Access it Anywhere?

The Answer's in the Cloud.

eTracker is a cellular modem and "virtual" cloud-based data logger in one (meaning you don't need to install a separate data logger). Simply connect your sensor and a power source to eTracker and you're done. Configure (or reconfigure) anytime from any Internet-connected device, and use Stevens-Connect to retrieve your data, or forward it to your favorite software system.

Technical Specifications

General

Range

600 to 1100 hPa (17.72 to 32.48 inch/hg)

Elevation

Sea level to 10,000 ft. (3048 m)

Resolution

0.1 hPa

Temp. operating range

-40°C to 55°C (-40°F to 131°F)

Temp. compensated range

-40°C to 55°C (-40°F to 131°F)

Accuracy

±0.35 hPa @ 20°C (68°F)

Long Term Stability:

±1.0 hPa (±0.03 in Hg) over full range or ±0.5 hPa over any 200 hPa range
±1.0 hPa in 1 year

Electrical

Analog output

0-1, 0-2, 0-2.5 or 0-5 VDC
(Analog output automatically adjusts from zero to full scale for range selected.)

Digital output

RS-232, RS-485 & SDI-12

Digital protocol

ASCII Terminal Mode
RTU for RS-232 and RS-485.

Baud rates

1200, 2400, 4800, 9600, & 19.2K

Power requirement

10 mA @ 12 VDC, typical

Power range

6-16 VDC

Physical

Weight

8.8 oz. (250 g)